Xylem Heat Transfer Equipment
Parent Company of Standard Xchange and ITT Standard / American Standard)
Pre-engineered and engineered (TEMA) Shell and Tube, Plate and Frame, Air cooled, and Brazed Plate heat exchangers. Many sizes shipped from stock.
Experience. Perhaps you're looking for a basic shell-and-tube heat exchanger. Or maybe your application requires something more complex, like a sophisticated, precision-engineered unit. Whether you are looking for air coolers, heat transfer coils, compact brazed, welded, gasketed plate units or packaged steam condensers, Standard Xchange has whatever it takes to meet your heat transfer requirements.
Xylem, formerly Standard Xchange, has been developing heat transfer solutions for more than 90 years, for just about every industry. Today, we offer the broadest range of product available anywhere. And we're ready to share the benefits of those years of research, design capability and experience in heat transfer in developing the best solutions for your applications.
Performance. Every Xylem heat exchanger is backed by top-notch technical expertise. This helps us make sure our products run efficiently and perform well. It also means you're assured of technical guidance throughout the process of evaluating, selecting, and installing the right heat exchanger. Our experts can help you define your needs, determine specifications, and answer questions; and they can even provide precise technical drawings and mechanical details, if needed.
Experience. Perhaps you're looking for a basic shell-and-tube heat exchanger. Or maybe your application requires something more complex, like a sophisticated, precision-engineered unit. Whether you are looking for air coolers, heat transfer coils, compact brazed, welded, gasketed plate units or packaged steam condensers, Standard Xchange has whatever it takes to meet your heat transfer requirements.
Xylem, formerly Standard Xchange, has been developing heat transfer solutions for more than 90 years, for just about every industry. Today, we offer the broadest range of product available anywhere. And we're ready to share the benefits of those years of research, design capability and experience in heat transfer in developing the best solutions for your applications.
Performance. Every Xylem heat exchanger is backed by top-notch technical expertise. This helps us make sure our products run efficiently and perform well. It also means you're assured of technical guidance throughout the process of evaluating, selecting, and installing the right heat exchanger. Our experts can help you define your needs, determine specifications, and answer questions; and they can even provide precise technical drawings and mechanical details, if needed.
With our in-house, state-of-the-art lab, we can test equipment to your precise application before anything is shipped to you. In short, we'll work with you every step of the way to make sure you get the exact solution you need for your heat transfer problems.
Contact Us for more information. (770) 345-0010
Contact Us for more information. (770) 345-0010
Pre-Engineered Shell and Tube Heat Exchangers:
Standard Units have a (1-2) week delivery after purchase order is received.
Expediting options are available please contact us for more information (770) 345-0010.
Xylem/Standard Xchange Pre-Engineered Series Brochure: BCF/ SSCF/ SX2000/ B300
Expediting options are available please contact us for more information (770) 345-0010.
Xylem/Standard Xchange Pre-Engineered Series Brochure: BCF/ SSCF/ SX2000/ B300
Model BCF, HCF, HFF (Brass shell)-(Brochure)
Straight Tube, Fixed-tubesheet. 1,2 and 4 pass options covering areas as large as 247 Sq. Ft. Shell diameters from 2" through 8". 1/4", 3/8" and 5/8" OD tube options. Custom design features include special tube lengths, nozzle orientations, feet locations, baffle spacing.
Applications: To heat or cool water or lube oil; condense steam. Use for auxiliary machinery, turbines, engines, compressors and lasers.
Excellent choice for pilot plants.
Straight Tube, Fixed-tubesheet. 1,2 and 4 pass options covering areas as large as 247 Sq. Ft. Shell diameters from 2" through 8". 1/4", 3/8" and 5/8" OD tube options. Custom design features include special tube lengths, nozzle orientations, feet locations, baffle spacing.
Applications: To heat or cool water or lube oil; condense steam. Use for auxiliary machinery, turbines, engines, compressors and lasers.
Excellent choice for pilot plants.
Model SSCF (All 316 stainless steel wetted materials)-(Brochure)
Straight Tube, Fixed-tubesheet. All fluid contact parts of 316 stainless steel. Heat transfer surfaces ranging from 1.2 to 576 square feet with 1, 2 or 4 pass options. ASME Code options available. Flanged connections also available.
Applications: For heating or cooling corrosive fluids in chemical, pharmaceutical or refining processes.
Model SX2000 (Steel shell)-(Brochure)
Straight Tube - Fixed Tubesheet, 1, 2 and 4 pass options, covering areas as large as 136.7 square feet. Shell diameters 3 inches to 8 inches with tube lengths 8 inches up to 144 inches. ASME Code options available. Flanged connections also available.
Applications: To cool lube oil, fluids or jacket water, and for use where brass is not practical.
Straight Tube - Fixed Tubesheet, 1, 2 and 4 pass options, covering areas as large as 136.7 square feet. Shell diameters 3 inches to 8 inches with tube lengths 8 inches up to 144 inches. ASME Code options available. Flanged connections also available.
Applications: To cool lube oil, fluids or jacket water, and for use where brass is not practical.
Removable U-Tube Heat Exchangers (ASME Section VIII Div. 1 Code Stamp):
Model B300S, B300W, and SX2000U-(Brochure)
U-tube heat exchangers with copper tubes. 2, 4 and 6 pass models covering areas as large as 1900 square feet. Diameters from 4" to 29" Shell Diameters. 3/4" OD Tubes. ASME Code constructed. Available as B300S for Steam applications or B300W for Water applications. SX2000U only available with 3/8" OD tubes.
Applications: For heating water or other fluids, using steam or water as the heating/cooling medium.
U-tube heat exchangers with copper tubes. 2, 4 and 6 pass models covering areas as large as 1900 square feet. Diameters from 4" to 29" Shell Diameters. 3/4" OD Tubes. ASME Code constructed. Available as B300S for Steam applications or B300W for Water applications. SX2000U only available with 3/8" OD tubes.
Applications: For heating water or other fluids, using steam or water as the heating/cooling medium.
Custom Engineered Shell and Tube Units :
Century Series Units-(Brochure)
Our Century series offers a wide variety of design options such as:
Century Series Units-(Brochure)
Our Century series offers a wide variety of design options such as:
(C100) TEMA type AEP or BEP Straight tube, removable bundle, outside-packed floating head.
(C200) TEMA type AEM,BEM or NEN; Straight tube, fixed tubesheet, removable channel or bonnet, or (C210) integral channel
(C300) TEMA type AEU or BEU; U-tube, removable bundle or (C320) Suction-heater (open-end shell) construction
(C400) TEMA type AET or BET; Straight tube, internally bolted floating head, pull through construction with removable bundle
(C500) TEMA type AES or BES; Straight tube, internal clamp split ring, floating head, removable bundle
Single or multi-pass tube arrangements are available for maximum efficiency over a wide variety of tube flow volumes.An expansion joint can be added to some of these models to compensate for severe temperature differentials. Standard shell sizes from 3 inches through 31 inches in diameter; with custom designs up to 60 inches in diameter.The century series can meet TEMA "B", "C", and "R" specifications. Along with ASME Section VIII Div. 1 "U" stamp and ASME Section III "N" stamp.
Model CPK (removable straight tube unit)-(Brochure)
Straight tube, removable bundle, packed floating tubesheet. Single or two pass tube arrangements for maximum efficiency over a wide variety of tube side flow rates. Standard shell sizes from 3 inches through 31 inches in diameter; with custom designs up to 60 inches in diameter. Available in horizontal and vertical installations as well as stacked assemblies. TEMA type AEW or BEW. The CPK model can meet TEMA "B", "C", and "R" specifications. Along with ASME Section VIII Div. 1 "U" stamp and ASME Section III "N" stamp.
Straight tube, removable bundle, packed floating tubesheet. Single or two pass tube arrangements for maximum efficiency over a wide variety of tube side flow rates. Standard shell sizes from 3 inches through 31 inches in diameter; with custom designs up to 60 inches in diameter. Available in horizontal and vertical installations as well as stacked assemblies. TEMA type AEW or BEW. The CPK model can meet TEMA "B", "C", and "R" specifications. Along with ASME Section VIII Div. 1 "U" stamp and ASME Section III "N" stamp.
Air Cooled Heat Exchangers:
Airex-(Brochure)
Compact bar and plate design, air-cooled unit. Up to 65% smaller than Fin Tube designs.
Application: Oil cooling with air, where compact size and rugged construction are a must. Unit uses a louvered fin design for use in clean environments.
Fanex-(Brochure)
FanEx (Air/Oil) Heat Exchangers with Amaspher Turbulation have heavy duty direct drive fans, copper headers with brazed joints and galvaneal steel housings. All Air/Oil models feature exclusive, patented Amaspher turbulation to mix oil for better cooling in less space. Twelve standard sizes with oil flows from 2 to 180 gallons per minute.
Application: For cooling oil or other fluids with air, where compact size, cooling efficiency, safety and quiet operation are important.
Airex-(Brochure)
Compact bar and plate design, air-cooled unit. Up to 65% smaller than Fin Tube designs.
Application: Oil cooling with air, where compact size and rugged construction are a must. Unit uses a louvered fin design for use in clean environments.
Fanex-(Brochure)
FanEx (Air/Oil) Heat Exchangers with Amaspher Turbulation have heavy duty direct drive fans, copper headers with brazed joints and galvaneal steel housings. All Air/Oil models feature exclusive, patented Amaspher turbulation to mix oil for better cooling in less space. Twelve standard sizes with oil flows from 2 to 180 gallons per minute.
Application: For cooling oil or other fluids with air, where compact size, cooling efficiency, safety and quiet operation are important.
Brazed Plate Heat Exchangers:
BP models available with copper or nickel brazing and 316 S/S plates-(Brochure)
Vacuum-brazed, stacked plate construction, Copper Braze as standard with optional Nickel braze material available. Max Flow - 800 GPM with areas up to 365 Sq. Ft. Connections are 316L stainless steel and range from 1/2" OD to 4" OD connections in MNPT, FNPT, Sweat, SAE threaded, Flanged, Victaulic grooved, Hose barb, etc. with custom connections available. Optional threaded studs or integral mounting bracket. Available codes include UL, CRN, ASME Code and CE/PED.
Applications: For general purpose oil, water and gas cooling.
Use on compressors, hydraulic packages, lasers and diesel engines.
Excellent for use as refrigerant evaporators, condensers, subcoolers and desuperheaters.
Plate and Frame Heat Exchangers:
Gasketed Plate and Frame units- (Brochure)
Plate and Frame heat exchangers use a combination of chevron-style heat transfer plates sequenced between a frame plate and pressure plate. The heat transfer plates have holes at the four corners forming a header that distribute the respective flows to the opposite sides of each plate when the plates align. The fluids are confined to the heat transfer surface of the plate or the port as appropriate with elastomer gaskets. Max Flow - up to 23,500 GPM with heat transfer areas up to 20,000 Sq. Ft. 1" to 2.5" NPT nozzle connections. 3" to 18" ANSI Studded connections.
Applications: For close temperature approach of fluids to maximize heat recovery. Semi-welded Plateflow exceptional for refrigerant, aggressive chemical, or any applications where reducing the fluid's contact with elastomers is desired. Free-Flow feature is ideal for heat reclamation in pulp and paper or chemical processing, where wash water, white water, fibrous water slurries or high viscosity fluids are used. Double wall plates to eliminate possibility of fluid intermixing.
XYLEM
Contact us for more information on the above products:
Email: sales@southgatepe.com
Phone: (770) 345-0010